Call(424) 424-2302

Rational iCombi: Scaled Valves Took Out the Control Board

Got a code on the screen? Send us a photo. Most of the time it tells us what to bring.

Send a photo of the screen

The call

A buffet restaurant's Rational iCombi stopped working properly. Nothing dramatic happened on the day. The failure had been building for a long time.

What we found

The water valve block was heavily scaled. To open valves clogged with scale, the pump control board had to work much harder on every cycle, and the relays on that electronic module ran overloaded day after day. Eventually both gave out: the valve block and the pump control board.

The warning signs

For a long time before the failure, the valves were clicking audibly. The staff heard it but did not pay attention. At that stage, replacing the valve block alone would have fixed it. Because it was left, the control board failed too, and the repair grew.

Why it happened

The unit had no water filter, and descaling was not done on schedule. Hard water did the rest.

The repair

Our parts partners delivered the next day, and the day after the diagnosis we replaced the water valve block and the pump control board, then ran the oven through steam, cleaning and full test cycles.

What we recommend

Service the unit on time

Regular preventive maintenance and an early call at the first sign of trouble cost far less than a repair like this one.

Call (424) 424-2302

Brand, model and the code on the screen.

Tell us what the oven is doing

(424) 424-2302

Call, or send the form with a photo of the screen. We reply within working hours, Monday to Saturday.

Thanks. We have your request and will call you shortly.
Call nowSend error code